Tool Monitoring

we design solutions

BK MIKRO: The Control Units

Minimum Size, Maximum Performance

  • Compact design for easy top hat rail mounting.
  • ARM9 with high processing power and low current consumption.
  • Mini-USB socket to connect any control unit to a PC for configuring a system.
  • Easy to use software with monitoring capabilities.
  • Small circular connector for connecting the scanner .
  • Digital I/O or PROFIBUS to network to the machine control.
  • Galvanically isolated inputs and outputs guarantee a high degree of operational safety and interference resistance.
  • Hardware–based cable break detection.

control units BK MIKRO9

BK MIKRO91/92 Premium

BK MIKRO91 92 Premium BKM91:
  • PROFIBUS interface for direct field bus connection to machine control
  • Mini-USB for PC-connection
  • 3 digital control inputs (start, teach, freely configurable)
  • 2 relay outputs (OK, KO)
  • Scanner connection
  • Pluggable supply voltage
  • Opening for top hat rail plug for optional connection of I/O extension module
BKM92:
  • Same features as BKM91, but without PROFIBUS interface

Technical data

Housing Insulation material, protection class II, built-in type
Protection class IP20
Dimensions 22.6 mm x 99 mm x 113.6 mm
Mounting Profile rail 35 mm acc. DIN EN 50022
Power supply voltage 24 VDC ±20 % PELV, Imax = 0,4 A
Power consumption Max. 10 VA
Control voltage 24 VDC ±20 % PELV
Inputs Galvanically isolated, input current approx. 5 mA, pulse duration 30 ms min.
Switch outputs 2x 30 VDC, 2 A max.
Life cycle of relay 105 switching cycles min.
Connections
  • Pluggable screw terminals for voltage supply, relay outputs, control inputs, scanner
  • Mini-USB
  • PROFIBUS, Sub-D, 9 pin (only with BKM91 Premium)
Climate conditions According class 3K3 acc. EN 50178
Ambient temperature 0 °C up to +50 °C

 

BK MIKRO93 Basic

BKM93BASIC
  • Mini-USB for PC-connection
  • 3 digital control inputs (start, teach, freely configurable)
  • 2 relay outputs (OK, KO)
  • Scanner connection
  • Pluggable supply voltage
  • Opening for top hat rail plug for optional connection of I/O extension module
  • 4 LEDs for status display

Technical data

Housing Insulation material, protection class II, built-in type
Protection class IP20
Dimensions 22.6 mm x 99 mm x 113.6 mm
Mounting Profile rail 35 mm acc. DIN EN 50022
Power supply voltage 24 VDC ±20 % PELV, Imax = 0,4 A
Power consumption Max. 10 VA
Control voltage 24 VDC ±20 % PELV
Inputs Galvanically isolated, input current approx. 5 mA, pulse duration 30 ms min.
Switch outputs 2x 30 VDC, 2 A max.
Life cycle of relay 105 switching cycles min.
Connections
  • Pluggable screw terminals for voltage supply, relay outputs, control inputs, scanner
  • Mini-USB
Climate conditions According class 3K3 acc. EN 50178
Ambient temperature 0 °C up to +50 °C

 

BK MIKRO9I/O Extension Module

 BK MIKRO9IO
  • 10 digital inputs to select / activate up to 512 different tool positions
  • 2 digital outputs for free configuration
  • 3 rotary switches (selecting the scanner, feeding in the scanning angle)
  • 8 dip switches (selecting the type of monitoring, defining the rotational direction, defining the scanning intensity, selecting the tolerance range etc.)
  • 4 LEDs for current status display
  • Top hat rail plugs

Technical data

Housing Insulation material, protection class II, built-in type
Protection class IP20
Dimensions 22.6 mm x 99 mm x 113.6 mm
Mounting Profile rail 35 mm acc. DIN EN 50022
Control voltage 24 VDC ±20 % PELV
Inputs Input current approx. 5 mA, pulse duration 30 ms min.
Switch outputs 2 high side switches with maximum output current 0.5 A
Connections

Pluggable screw terminals for 10 inputs, 2 outputs (with voltage supply)

Climate conditions According class 3K3 acc. EN 50178
Ambient temperature 0 °C up to +50 °C