Tool Monitoring

we design solutions

BK MIKRO LIN

Tool Monitoring System for Linear Scanning

This system monitors geometries which require longitudinal scanning, especially in cases where rotary scanning is inappropriate or impossible, for example cavities, bore holes, limited space arrangements or critical coolant pressure.

tool monitoring bk mikro lin

Features:

  • Monitoring of the scanning position whose precise location has been previously entered by "Teach-in", e.g. to carry out a tool check before each working cycle (tool monitoring), especially for "Multi":8 scanning positions can be coded.
  • Monitoring a scanning range freely selectable via two adjusting switches, e.g. to check cavities with varying depth (object monitoring), or to check bore holes (free
    space monitoring), only for "Multi".
  • Variants for the tip of the wand (also project-specific)
  • Two steps for scanning intensity
  • Various ranges of tolerance for "O.K." message
  • Indication of the scanning result by two LEDs for "O.K." and "K.O." at the control unit
  • Detection of cable breaks

Technical data scanner

Anodized aluminum
Protection type IP 64
Scanning tip Exchangeable, thread M3x6
Connection Small circular connector M12x1, 6 pin
Ambient temperature 0°C up to +80°C
Storage temperature -25°C up to +80°C
Scanning cycles > 5 million at minimum scanning intensity

Technical data control unit

Insulating material housing, protection class II, built-in unit, IP 20
Dimensions (WxHxD) 40 x 75 x 107.5 mm
Case mountings Sectional rail, 35 mm, to DIN EN 50022
Power supply voltage 230 VAC, 120 VAC, 24 VDC (depending on model)
Power consumption 6 VA max.
Control voltage 24 VDC (internal/external)
Inputs Galvanically isolated, Input current 5 mA approx., Pulse duration 6 ms min.
Switched outputs 2 x 250 VAC / 30 VDC, 2 A max.
Making/breaking capacity 500 VA / 60 W (max.) . 10 mA min. at 10 V
Operational life of relay 5 x 107 switching cycles
Connections Plug-in screw terminals for connecting
- power supply, control inputs, selection inputs (only for "Multi"), relay outputs
Scanner socket to DIN 45322, 6 pin
Climatological conditions Classification 3K3 under EN 50178
Ambient temperature 0°C up to +50°C
Storage temperature -25°C up to +80°C

 

MSC Microcomputers Systems Components Tuttlingen GmbH · Rudolf-Diesel-Str. 17 · D-78532 Tuttlingen · Phone: +49 7461 925-200 · Fax: +49 7461 925-268